Micatron Installation Guides

Micatron Download Centre

Latest Micatron News

Micatrob Press Releases

LED Lighting Solutions

Micatron Dimming Switch for use with Dual Tapped Magnetic Ballasts

More Info...

Micatron Dimming Switch for use with Dual Tapped Magnetic Ballasts

Back to Technical Specifications

 

Micatron Dimming Switch for use with Dual Tapped Magnetic Ballasts

Technical Specification for the Micatron Dimming Switch
Switch Type Electromechanical Relay with Zero Crossing switching
Voltage 240V +/-10%
Load Handling 2 x 400W HID Lamps Max 60uF
Load Current Capacity 1,000W Tungsten 1,800VA Inductive
Dimming Times Default setting : Midnight to 05:30 G.M.T. or to Customers specification, quantity dependant
Circuit Power Consumption Less than 0.20W Switched On. No Power Consumption when Off.
Operating Temperature (Ta) -20 o C to +94 o C
Power Loss During Load Handling Negligable
Enclosure Material ABS
IP Rating IP65
EMC To EN50082-1 & EN55014
Dimentions L 86mm x W 49mm x H26mm

Notes:
•  The Dimming Switch will not interfere with lamp testing routines as it will ignore switching cycles of less than 30 minutes.
•  The Dimming Switch will always default to the highest switched level of the ballast. Standard gear options available:

70w dimming to 50w
100w dimming to 70w
150w dimming to 100w
250w dimming to 150w
400w dimming to 250w